Description:
1. Large capacity at 160 1/min: Large pressure at 210 kgf/cm2
2. Dual frequency terminals (50/60Hz)
3. Ann-dust and water proof structure based on IFC. Pub529 lp65.
Specification:
Model Coding
Nominal Dia
kgf/cm²
Maximum Operating Pressure
L/min
Maximum Flow
kgf/cm²
Allowable Back
Pressure
Maximum Shifting Frequency Tme/min
AC. DC
TS-G02
1/4
210
100
140
240
IEC Pub529 IP65
TS-G03
3/8
160 (DC). 130 (AC)
Nomenclature:
1. TS Series Number
2. Connecting method: Gasket mouting
3. 02: 1/4 03:3/8
Nominal dia 02:1/4 03:3/8
4. Spool types (See table for"spool symbols")
5. Spool Functions
C: Spring centered type
A: Spring offset type with SOL. a
B: Spring offset type with SOL. b
N: No spring type(no detent)
D: No spring type(no detent)
6. Voltage Symbols
A: AC110V B: AC220V P: DC24V
7. Design Number
8. See table for optional symbols